Home › FDA recalls › Philips Azurion 5M20
CLASS II · ModerateFDA

PHILIPS MEDICAL SYSTEMS NEDERLAND B.V. recalls Philips Azurion 5M20

📅 Dec 7, 2023 · 📍 Nationwide
Recalling company
PHILIPS MEDICAL SYSTEMS NEDERLAND B.V.
Product
Philips Azurion 5M20, Model Numbers: 722228 with Software release R2.2.0, R2.2.1, R2.2.3, R2.2.5 and R2.2.6 with the Roadmap Pro Software key
Reason
During the device phase of Roadmap Pro, a user may experience a dark image that is not clinically usable. The dark image may result after the user performs a pedal tap (shortly touching the footswitch pedal without generating an Xray image). The pedal tap may cause a dark image with the next fluoroscopy run.
Classification
Class II – may cause temporary or medically reversible health consequences
Recall date
Dec 7, 2023
Reported
Jun 10, 2026
Distribution
US Nationwide distribution.
Status
Ongoing
Quantity
51 units
Lot / codes
UDI (01)00884838099234(21)67, (01)00884838099234(21)49, (01)00884838099234(21)10, (01)00884838099234(21)36, (01)00884838099234(21)64, (01)00884838099234(21)110, (01)00884838099234(21)328, (01)00884838099234(21)149, (01)00884838099234(21)213, (01)00884838099234(21)45, (01)00884838099234(21)159, (01)00884838099234(21)18, (01)00884838099234(21)231, (01)00884838099234(21)61, (01)00884838099234(21)204, (01)00884838099234(21)273, (01)00884838099234(21)76, (01)00884838099234(21)150, (01)00884838099234(21)132, (01)00884838099234(21)189, (01)00884838099234(21)17, (01)00884838099234(21)47, (01)00884838099234(21)38, (01)00884838099234(21)87, (01)00884838099234(21)128, (01)00884838099234(21)32, (01)00884838099234(21)23, (01)00884838099234(21)25, (01)00884838099234(21)62, (01)00884838099234(21)181, (01)00884838099234(21)177, (01)00884838099234(21)48, (01)00884838099234(21)153, (01)00884838099234(21)79, (01)00884838099234(21)80, (01)00884838099234(21)157, (01)00884838099234(21)24, (01)00884838099234(21)187, (01)00884838099234(21)26, (01)00884838099234(21)29, (01)00884838099234(21)122, (01)00884838099234(21)127, (01)00884838099234(21)6, (01)00884838099234(21)123, (01)00884838099234(21)124, (01)00884838099234(21)92, (01)00884838099234(21)215, (01)00884838099234(21)91, (01)00884838099234(21)205, (01)00884838099234(21)20, (01)00884838099234(21)37a.
Company location
Best
Recall number
Z-2287-2026
Agency
U.S. Food and Drug Administration (FDA)

View official FDA notice ↗ Search recall number Z-2287-2026 in the FDA Enforcement Report. Also see FDA recall press releases.

If you use this product, check the lot, NDC or model number against the official notice and follow its instructions. Do not stop a prescribed medicine or remove a medical device without talking to your doctor or pharmacist. Report problems to FDA MedWatch. FoodRecallNow summarizes public FDA data and is not medical advice.